Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AIP Conf Proc ; 18212017.
Artigo em Inglês | MEDLINE | ID: mdl-34219824

RESUMO

One of the safety concerns with the delivery of therapeutic ultrasound is overheating of the transducer-skin interface due to poor or improper coupling. The objective of this research was to define a model that could be used to calculate the heating in the skin as a result of a novel, wearable long-duration ultrasound device. This model was used to determine that the maximum heating in the skin remained below the minimum threshold necessary to cause thermal injury over multiple hours of use. In addition to this model data, a human clinical study used wire thermocouples on the skin surface to measure heating characteristics during treatment with the sustained ultrasound system. Parametric analysis of the model determined that the maximum temperature increase is at the surface of the skin ranged from 40-41.8° C when perfusion was taken into account. The clinical data agreed well with the model predictions. The average steady state temperature observed across all 44 subjects was 40°C. The maximum temperature observed was less than 44° C, which is clinically safe for over 5 hours of human skin contact. The resultant clinical temperature data paired well with the model data suggesting the model can be used for future transducer and ultrasound system design simulation. As a result, the device was validated for thermal safety for typical users and use conditions.

2.
Artigo em Inglês | MEDLINE | ID: mdl-30078928

RESUMO

Therapeutic ultrasound is an established technique for biomodulation used by physical therapists. Typically it is used to deliver energy locally for the purpose of altering tissue plasticity and increasing local circulation. Access to ultrasound therapy has been limited by equipment and logistic requirements, which has reduced the overall efficacy of the therapy. Ultrasound miniaturization allows for development of portable, wearable, self-applied ultrasound devices that sidestep these limitations. Additionally, research has shown that the timescale of acoustic stimulation matters, and directly affects the quality of result. This paper describes a novel, long duration approach to therapeutic ultrasound and reviews the current data available for a variety of musculoskeletal conditions.

3.
Artigo em Inglês | MEDLINE | ID: mdl-25570019

RESUMO

One of the major challenges in the design of a new class of medical device is ensuring that the device will have a safe and effective user interface for the intended users. Human Factors Engineering addresses these concerns through direct study of how a user interacts with newly designed devices with unique features. In this study, a novel long duration, low intensity therapeutic ultrasound device is tested by 20 end users representative of the intended user population. Over 90% of users were able to operate the device successfully. The therapeutic ultrasound device was found to be reasonably safe and effective for the intended users, uses, and use environments.


Assuntos
Ergonomia , Adulto , Desenho de Equipamento , Ergonomia/instrumentação , Humanos , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/terapia , Inquéritos e Questionários , Fatores de Tempo , Terapia por Ultrassom , Adulto Jovem
4.
Artigo em Inglês | MEDLINE | ID: mdl-25788823

RESUMO

Osteoarthritis is one of the leading causes of disability in the aging population. Long duration, low intensity therapeutic ultrasound has had promising impact in animal models to slow the progression of the disease and provide joint relief. Two pilot studies were conducted using a novel, wearable platform for delivering ultrasound to evaluate the potential clinical benefits of ultrasound therapy on knee osteoarthritis. There was a pain reduction effect from using ultrasound, as high as fifty two percent in one study. As well, initial data demonstrates that mobility may be increased for patients experiencing mild to moderate arthritis of the knee.

5.
Ultrasound Med Biol ; 39(8): 1429-39, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23743101

RESUMO

Ultrasound therapy for pain and healing is a versatile treatment modality for musculoskeletal conditions that is used daily in rehabilitation clinics around the world. Our group designed and constructed a wearable, battery-operated, low-intensity therapeutic ultrasound (LITUS) device that patients could self-apply and operate during daily activity for up to 6 h. Thirty patients with chronic trapezius myofascial pain evaluated the LITUS system in a double-blind, placebo-controlled, 10-d study under institutional review board approval. While continuing their prescribed medication regimen, patients with the active device reported on average 1.94× reduction in pain and 1.58× improvement in health relative to placebo devices after 1 h of treatment. Both of these results were statistically significant (p < 0.05) for the first 2 d of the study. Male patients reported the majority of benefit, and there is a sex-treatment confound in the sample. The study indicates that wearable, long-duration LITUS technology improves mobile access to drug-free pain relief.


Assuntos
Dor Crônica/prevenção & controle , Síndromes da Dor Miofascial/prevenção & controle , Autocuidado/instrumentação , Terapia por Ultrassom/instrumentação , Adulto , Método Duplo-Cego , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Efeito Placebo , Resultado do Tratamento
6.
J Cell Sci ; 125(Pt 14): 3299-309, 2012 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-22505612

RESUMO

This study investigated the impact of cadherin binding differences on both cell sorting and GTPase activation. The use of N-terminal domain point mutants of Xenopus C-cadherin enabled us to quantify binding differences and determine their effects on cadherin-dependent functions without any potential complications arising as a result of differences in cytodomain interactions. Dynamic cell-cell binding measurements carried out with the micropipette manipulation technique quantified the impact of these mutations on the two-dimensional binding affinities and dissociation rates of cadherins in the native context of the cell membrane. Pairwise binding affinities were compared with in vitro cell-sorting specificity and ligation-dependent GTPase signaling. Two-dimensional affinity differences greater than five-fold correlated with cadherin-dependent in vitro cell segregation, but smaller differences failed to induce cell sorting. Comparison of the binding affinities with GTPase signaling amplitudes further demonstrated that differential binding also proportionally modulates intracellular signaling. These results show that differential cadherin affinities have broader functional consequences than merely controlling cell-cell cohesion.


Assuntos
Caderinas/genética , GTP Fosfo-Hidrolases/metabolismo , Mutação Puntual , Sequência de Aminoácidos , Animais , Células CHO , Caderinas/biossíntese , Caderinas/metabolismo , Cálcio/farmacologia , Sinalização do Cálcio , Adesão Celular/fisiologia , Cricetinae , Ativação Enzimática , Eritrócitos/citologia , Eritrócitos/metabolismo , Eritrócitos/fisiologia , Citometria de Fluxo , Humanos , Camundongos , Transdução de Sinais , Xenopus laevis , Proteínas rac1 de Ligação ao GTP/metabolismo , Proteína rhoA de Ligação ao GTP/metabolismo
7.
J Cell Sci ; 125(Pt 10): 2478-85, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22344255

RESUMO

We present direct evidence that the N-glycosylation state of neural cadherin impacts the intrinsic kinetics of cadherin-mediated intercellular binding. Micropipette manipulation measurements quantified the effect of N-glycosylation mutations on intercellular binding dynamics. The wild-type protein exhibits a two-stage binding process in which a fast, initial binding step is followed by a short lag and second, slower transition to the final binding stage. Mutations that ablate N-glycosylation at three sites on the extracellular domains 2 and 3 of neural cadherin alter this kinetic fingerprint. Glycosylation does not affect the affinities between the adhesive N-terminal domains, but instead modulates additional cadherin interactions, which govern the dynamics of intercellular binding. These results, together with previous findings that these hypo-glycosylation mutations increase the prevalence of cis dimers on cell membranes, suggest a binding mechanism in which initial adhesion is followed by additional cadherin interactions, which enhance binding but are modulated by N-glycosylation. Given that oncogene expression drives specific changes in N-glycosylation, these results provide insight into possible mechanisms altering cadherin function during tumor progression.


Assuntos
Caderinas/química , Caderinas/metabolismo , Motivos de Aminoácidos , Animais , Células CHO , Caderinas/genética , Adesão Celular , Cricetinae , Eritrócitos/metabolismo , Glicosilação , Humanos , Cinética , Camundongos , Ligação Proteica , Estrutura Terciária de Proteína
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...